Excerpts
in § 63.11410(j)(1). As an alternative to conducting a performance test using Method 5 or 5D to determine the concentration of PM, you may use Method 29 of 40 CFR part 60, appendix A-8 of this chapter to determine the concentration of HAP metals. ASTM D6784-24 (incorporated by reference, see § 63.14) may also be used in lieu of Method 29, if the target compound is mercury and concentrations are approximately 0.5 to 100 micrograms per cubic meter. You have demonstrated compliance if the overall reduction of either HAP metals or total PM is equal