This database provides information on standards that have been incorporated by reference into the US Code of Federal Regulations (CFR). To obtain copies of the standards referenced, information should be provided in the referenced CFR section about how to obtain a copy. Alternatively, individuals can check with the standards publisher, a standards resellers or for a limited number of standards used in regulations, consult the American National Standards Institute (ANSI) Incorporated by Reference (IBR) Portal. This portal provides a mechanism for limited and free access to some of the standards that have been incorporated by reference in the U.S. Code of Federal Regulations (CFR).
Incorporated by (Agency) | FR Citation | CFR Citation Sort ascending | Document Number | Document Edition / Year | Title of Standard | Standard Publishing Organization |
---|---|---|---|---|---|---|
Rural Utilities Service | 7 CFR 1728.97(e)(1) | AWPA A1 | 2006 | Standard Methods for Analysis of Creosote and Oil-Type Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.97(c)(2) | ANSI O5.3 | 2008 | American National Standard for Wood Poles and Wood Products, Solid Sawn-Wood Crossarms & Braces—Specifications & Dimensions | American National Standards Institute | |
Research and Special Programs Administration | 7 CFR 1728.97(c)(1) | ANSI O5.2 | 2006 | American National Standard for Wood Products, Structural Glued Laminated Timber for Utility Structures | American National Standards Institute | |
Rural Utilities Service | 7 CFR 1728.97(b)(1) | AITC 200 | 2004 | Inspection Manual | American Institute of Timber Construction | |
Rural Utilities Service | 7 CFR 1728.97(a)(9) | RUS Bulletin 50-34 (D-6) | 1970 | RUS Specification for Secondary Swinging Clevises | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(8) | RUS Bulletin 50-33 (D-5) | 1951 | RUS Specification for Single and Double Upset Spool Bolts | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(7) | RUS Bulletin 50-32 (D-4) | 1950 | RUS Specification for Steel Crossarm Mounted Pins | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(6) | RUS Bulletin 50-31 (D-3) | 1979 | RUS Specification for Pole Top Pins | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(5) | RUS Bulletin 50-23 (DT-18) | 1971 | RUS Specification for 60-inch Wood Crossarm Braces | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(4) | RUS Bulletin 50-19 (DT-7) | 1953 | RUS Specification for Clevis Bolts | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(3) | RUS Bulletin 50-16 (DT-4) | 1952 | RUS Specification for Angle Suspension Brackets | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(26) | RUS Bulletin 1728F-811 | 1998 | Electric Transmission Specifications and Drawings, 115 kV to 230 kV (3–98). | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(25) | RUS Bulletin 1728F-810 | 1998 | Electric Transmission Specifications and Drawings, 34.5 kV to 69 kV (3–98) | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(24) | RUS Bulletin 1728F-806 (D-806) | 2000 | Specifications and Drawings for Underground Electric Distribution | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(23) | RUS Bulletin 1728F-804 (D-804) | 2005 | Specification and Drawings for 12.47/7.2 kV Line Construction | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(22) | RUS Bulletin 1728F-803 | 1998 | Specifications and Drawings for 24.9/14.4 kV Line Construction | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(21) | RUS Bulletin 1728F-700 | 2001 | Specification for Wood Poles, Stubs and Anchor Logs | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(20) | RUS Bulletin 50-91 (S-3) | 1978 | RUS Specification for Step-Down Distribution Substation Transformers (34.4–138 kV) | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(2) | RUS Bulletin 50-15 (DT-3) | 1951 | RUS Specification for Pole Top Pins | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(19) | RUS Bulletin 50-74 (U-6) | 1979 | RUS Specification for Secondary Pedestals (600 Volts and Below) | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(18) | RUS Bulletin 50-73 (U-5) | 1977 | RUS Specification for Pad-Mounted Transformers (Single and Three-Phase) | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(17) | RUS Bulletin 50-72 (U-4) | 1979 | RUS Specification for Electrical Equipment Enclosures (5–35 kV) (10–79) | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(16) | RUS Bulletin 50-60 (T-9) | 1971 | RUS Specification for Single Pole Steel Structures Complete with Arms | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(15) | RUS Bulletin 50-56 (T-3) | 1953 | RUS Specification for Steel Plate Anchors for Transmission Lines | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(14) | RUS Bulletin 50-55 (T-2) | 1953 | RUS Specification for Overhead Ground Wire Support Brackets | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(13) | RUS Bulletin 50-41 (D-15) | 1951 | RUS Specification for Service Wireholders | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(12) | RUS Bulletin 50-40 (D-14) | 1951 | RUS Specification for Pole Top Brackets for Channel Type Pins | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(11) | RUS Bulletin 50-36 (D-8) | 1952 | RUS Specification for Service Deadend Clevises | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(10) | RUS Bulletin 50-35 (D-7) | 1952 | RUS Specification for Service Swinging Clevises | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(a)(1) | RUS Bulletin 50-4 (D-801) | 1986 | Specification and Drawings for 34.5/19.9 kV Distribution Line Construction (11–86). | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(D) | AWPA A9 | 2001 | Standard Method for Analysis of Treated Wood and Treating Solutions by X-ray Spectroscopy | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(D) | AWPA A2 | 2008 | Standard Methods for Analysis of Waterborne Preservatives and Fire-Retardant Formulations | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(D) | AWPA A7 | 2004 | Standard Wet Ashing Procedure for Preparing Wood for Chemical Analysis | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(C) | AWPA A9 | 2001 | Standard Method for Analysis of Treated Wood and Treating Solutions by X-ray Spectroscopy | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(C) | AWPA A5 | 2005 | Standard Methods for Analysis of Oil-Borne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(B) | AWPA A9 | 2001 | Standard Method for Analysis of Treated Wood and Treating Solutions by X-ray Spectroscopy | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(B) | AWPA A5 | 2005 | Standard Methods for Analysis of Oil-Borne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(A) | AWPA A6 | 2001 | Method for the Determination of Oil-Type Preservatives and Water in Wood | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(ii) | AWPA A3 | 2008 | Standard Methods for Determining Penetration of Preservatives and Fire Retardants | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1) | AWPA M2 | 2007 | Standard for Inspection of Treated Timber Products | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(e)(3) | AWPA M3 | 2005 | Standard Quality Control Procedures for Wood Preserving Plants | State of Hawaii, Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.202(e)(1) | AWPA M3 | 2005 | Standard Quality Control Procedures for Wood Preserving Plants | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(4) | AWPA A5 | 2005 | Standard Methods for Analysis of Oil-Borne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(4) | AWPA P8 | 2008 | Standard for Oil-Borne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(4) | AWPA P9 | 2006 | Standard for Solvents and Formulations for Organic Preservative Systems | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(3) | AWPA P8 | 2008 | Standard for Oil-Borne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(3) | AWPA P9 | 2006 | Standard for Solvents and Formulations for Organic Preservative Systems | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(2) | AWPA A2 | 2008 | Standard Methods for Analysis of Waterborne Preservatives and Fire-Retardant Formulations | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(2) | AWPA P5 | 2008 | Standard for Waterborne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(1) | AWPA P1/13 | 2006 | Standard for Coal Tar Creosote for Land and Fresh Water and Marine (Coastal) Water Use | American Wood Protection Association |