This database provides information on standards that have been incorporated by reference into the US Code of Federal Regulations (CFR). To obtain copies of the standards referenced, information should be provided in the referenced CFR section about how to obtain a copy. Alternatively, individuals can check with the standards publisher, a standards resellers or for a limited number of standards used in regulations, consult the American National Standards Institute (ANSI) Incorporated by Reference (IBR) Portal. This portal provides a mechanism for limited and free access to some of the standards that have been incorporated by reference in the U.S. Code of Federal Regulations (CFR).
Incorporated by (Agency) Sort descending | FR Citation | CFR Citation | Document Number | Document Edition / Year | Title of Standard | Standard Publishing Organization |
---|---|---|---|---|---|---|
Rural Utilities Service | 7 CFR 1755.910(d)(6)(iii) | ASTM D523 | 1989 | Standard Test Method for Specular Gloss | ASTM International | |
Rural Utilities Service | 7 CFR 1755.390(a)(7) | ASTM B193 | 1987 | Standard Test Method for Resistivity of Electrical Conductor Materials | ASTM International | |
Rural Utilities Service | 7 CFR 1755.405(g)(4) | IEEE 743 | 1984 | Standard Methods and Equipment for Measuring the Transmission Characteristics of Analog Voice Frequency Circuits | Institute of Electrical and Electronics Engineers | |
Rural Utilities Service | 7 CFR 1755.703(d) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.860(i)(4)(v) | ASTM A505 | 1987 | Standard Specification for General Requirements for Steel, Sheet and Strip, Alloy, Hot-Rolled and Cold-Rolled | ASTM International | |
Rural Utilities Service | 7 CFR 1755.870(g)(5)(iii) | ASTM D4565 | 1990 | Standard Test Method for Physical and Environmental Performance Properties of Insulations and Jackets for Telecommunication Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1755.890(k)(10)(i) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.903(c)(2)(i) | ASTM D4565 | 1999 | Standard Test Methods for Physical and Environmental Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1728.97(e)(3) | AWPA A3 | 2008 | Standard Methods for Determining Penetration of Preservatives and Fire Retardants | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1755.902(d)(1) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.902(n)(1)(ii) | ASTM A640 | 1997 | Standard Specification for Zinc-Coated Steel Strand for Messenger Support of Figure 8 Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1755.910(g)(2)(iii)(A) | ASTM B539 | 1990 | Standard Test Method for Measuring Contact Resistance of Electrical Connections (Static Contacts) | ASTM International | |
Rural Utilities Service | 7 CFR 1755.390(i)(10) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1728.97(a)(8) | RUS Bulletin 50-33 (D-5) | 1951 | RUS Specification for Single and Double Upset Spool Bolts | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.390(k)(8)(iii)(A) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.522(k)(1) | Bellcore SR-TSV-002275 | 1990 | BOC Notes on the LEC Networks-1990, Issue 1 | Bell Communications Research | |
Rural Utilities Service | 7 CFR 1755.703(j)(2) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.860(m)(4)(i) | ASTM D4566 | 1990 | Standard Test Method for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1755.506(dd) | 7 CFR 1755.505 | 2012 | Buried services | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.870(i)(3) | NFPA 70 | 1993 | National Electrical Code | National Fire Protection Association | |
Rural Utilities Service | 7 CFR 1755.890(l)(1) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.903(l)(5) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.97(b)(16) | RUS Bulletin 1753F-152, Form 515c | 2001 | Specifications and Drawings for Construction of Aerial Plant | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(e)(10) | AWPA P1/P13 | 2006 | Standard for Creosote Preservative | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1755.910(a)(7) | ASTM D2247 | 1992 | Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity | ASTM International | |
Rural Utilities Service | 7 CFR 1728.202(d)(2) | AWPA A2 | 2008 | Standard Methods for Analysis of Waterborne Preservatives and Fire-Retardant Formulations | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1755.390(i)(7) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1728.97(a)(22) | RUS Bulletin 1728F-803 | 1998 | Specifications and Drawings for 24.9/14.4 kV Line Construction | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.390(s)(2) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.702(e)(4) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.860(a)(6) | ASTM D4872 | 1988 | Standard Test Method for Dielectric Testing of Wire and Cable Filling Compounds | ASTM International | |
Rural Utilities Service | 7 CFR 1755.870(a)(5) | EIA 359-A | 1984 | Standard Colors for Color Identification and Coding | Electronic Industries Association | |
Rural Utilities Service | 7 CFR 1755.890(c)(2) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.522(a)(8) | IEEE 455 | 1985 | Standard Test Procedure for Measuring Longitudinal Balance of Telephone Equipment Operating in the Voice Band | Institute of Electrical and Electronics Engineers | |
Rural Utilities Service | 7 CFR 1755.890, Appendix A (III)(5)(c) | ASTM D4565 | 1990 | Standard Test Method for Physical and Environmental Performance Properties of Insulations and Jackets for Telecommunication Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1728.201(h)(2)(i) | AWPA A9 | 2001 | Standard Method for Analysis of Treated Wood and Treating Solutions by X-ray Spectroscopy | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1755.910(a)(7) | ASTM D4568 | 1986 | Standard Test Method for Evaluating Compatibility Between Cable Filling and Flooding Compounds and Polyolefin Cable Materials | ASTM International | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(D) | AWPA A9 | 2001 | Standard Method for Analysis of Treated Wood and Treating Solutions by X-ray Spectroscopy | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1755.390(k)(5)(ii) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.890(o)(2) | RUS Bulletin 345-54, PE-52 | 1971 | RUS Specification for Telephone Cable Splicing Connectors | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.405(b)(4) | IEEE 743 | 1984 | Standard Methods and Equipment for Measuring the Transmission Characteristics of Analog Voice Frequency Circuits | Institute of Electrical and Electronics Engineers | |
Rural Utilities Service | 7 CFR 1755.702(i)(2) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.860(b)(5)(ii) | ASTM D4101 | 1982 | Standard Specification for Propylene Plastic Injection and Extrusion Materials | ASTM International | |
Rural Utilities Service | 7 CFR 1755.870(b)(12)(iii) | ASTM D4565 | 1990 | Standard Test Method for Physical and Environmental Performance Properties of Insulations and Jackets for Telecommunication Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1755.890(i)(5)(iv) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.870(l)(2) | RUS Bulletin 345-54, PE-52 | 1997 | RUS Specification for Telephone Cable Splicing Connectors | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.902(l)(4)(iv) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.506(a) | 7 CFR 1755.702 | 2012 | Copper coated steel reinforced (CCSR) aerial service wire | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.901(f)(4) | ITU-T Recommendation G.657 | 1993 | Series G: Optical fibre cables, Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network | International Telecommunication Union--Telecommunication | |
Rural Utilities Service | 7 CFR 1755.902(r)(14) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | Insulated Cable Engineers Association |