This database provides information on standards that have been incorporated by reference into the US Code of Federal Regulations (CFR). To obtain copies of the standards referenced, information should be provided in the referenced CFR section about how to obtain a copy. Alternatively, individuals can check with the standards publisher, a standards resellers or for a limited number of standards used in regulations, consult the American National Standards Institute (ANSI) Incorporated by Reference (IBR) Portal. This portal provides a mechanism for limited and free access to some of the standards that have been incorporated by reference in the U.S. Code of Federal Regulations (CFR).
Incorporated by (Agency) Sort descending | FR Citation | CFR Citation | Document Number | Document Edition / Year | Title of Standard | Standard Publishing Organization |
---|---|---|---|---|---|---|
Rural Utilities Service | 7 CFR 1755.390(p)(5)(i) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.704(c)(2) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.503(j) | NFPA 70 | 1999 | National Electrical Code | National Fire Protection Association | |
Rural Utilities Service | 7 CFR 1755.702(a)(1) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.860(m)(7)(i) | ASTM D4566 | 1990 | Standard Test Method for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1755.870(n)(2) | ASTM E29 | 1990 | Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications | ASTM International | |
Rural Utilities Service | 7 CFR 1755.890(l)(4) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.903(l)(3) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.910(a)(7) | ASTM G23 | 1990 | Standard Practice for Operating Light Exposure Apparatus (Carbon Arc Type) With and Without Water for Exposure of Nonmetallic Materials | ASTM International | |
Rural Utilities Service | 7 CFR 1755.910(a)(7) | ASTM D2565 | 1992 | Standard Practice for Operating Xenon Arc-Type Light-Exposure Apparatus With or Without Water for Exposure of Plastics | ASTM International | |
Rural Utilities Service | 7 CFR 1755.97(b)(15) | RUS Bulletin 1753F-151, Form 515b | 2001 | Specifications and Drawings for Construction of Underground Plant | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.902(l)(4)(iv) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.902(i)(2) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1728.202(b)(10)(ii) | AITC 200 | 2004 | Inspection Manual | American Institute of Timber Construction | |
Rural Utilities Service | 7 CFR 1755.390(i)(13) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.397(b)(3) | Bellcore TR-NWT-000303 | 1992 | Integrated Digital Loop Carrier System Generic Requirements, Objectives, and Interface | Bell Communications Research | |
Rural Utilities Service | 7 CFR 1755.860(a)(6) | ASTM D257 | 1991 | Standard Test Method for DC Resistance of Conductance of Insulating Materials | ASTM International | |
Rural Utilities Service | 7 CFR 1755.200(e)(17) | RUS Bulletin 345-63 | 2012 | RUS Specification for Acceptance Tests and Measurements of Telephone Plant, PC–4 | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.702(f)(4) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.870(a)(6) | ASTM B736 | 1992 | Standard Specification for Aluminum, Aluminum-Alloy and Aluminum-Clad Steel Cable Shielding Stock | ASTM International | |
Rural Utilities Service | 7 CFR 1755.890(f)(2) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1728.202(b)(3) | RUS Bulletin 1728F-700 | 2011 | RUS Specification for Wood Poles, Stubs and Anchor Logs | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.903(p)(2) | ICEA S-87-640 | 2006 | Standard for Optical Fiber Outside Plant Communications Cable, 4th edition | International Telecommunication Union--Telecommunication | |
Rural Utilities Service | 7 CFR 1755.910(a)(7) | ASTM B117 | 1990 | Standard Practice for Operating Salt Spray (Fog) Apparatus | ASTM International | |
Rural Utilities Service | 7 CFR 1755.505(c) | 7 CFR 1755.200 | 2012 | Splicing copper and fiber optic cables | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1728.97(e)(13) | AWPA P9 | 2006 | Standards for Solvents and Formulations for Organic Preservative Systems | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(d)(3) | AWPA P8 | 2008 | Standard for Oil-Borne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1755.390(i)(9) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1728.97(a)(14) | RUS Bulletin 50-55 (T-2) | 1953 | RUS Specification for Overhead Ground Wire Support Brackets | Rural Utilities Service, U.S. Department of Agriculture | |
Rural Utilities Service | 7 CFR 1755.405(e)(6) | IEEE 743 | 1984 | Standard Methods and Equipment for Measuring the Transmission Characteristics of Analog Voice Frequency Circuits | Institute of Electrical and Electronics Engineers | |
Rural Utilities Service | 7 CFR 1755.860(e)(4) | ASTM D4872 | 1988 | Standard Test Method for Dielectric Testing of Wire and Cable Filling Compounds | ASTM International | |
Rural Utilities Service | 7 CFR 1755.703(b)(5) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.870(b)(5)(i) | ASTM D1248 | 1989 | Standard Specification for Polyethylene Plastics Molding and Extrusion Materials | ASTM International | |
Rural Utilities Service | 7 CFR 1755.890(i)(5)(vi) | ASTM B224 | 1980 | Standard Classification of Coppers | ASTM International | |
Rural Utilities Service | 33 CFR 154, Appendix A, 8.6 | ASME B&PV Code | 2005 | Section VIII, Division 1, Pressure Vessels | American Society of Mechanical Engineers | |
Rural Utilities Service | 7 CFR 1755.901(f)(2) | ITU-T Recommendation G.655 | 2006 | Series G: Transmission Systems and Media, Digital Systems and Networks, Transmission media characteristics—Optical fibre cables, Characteristics of a non-zero dispersion-shifted single-mode optical fibre and cable | International Telecommunication Union--Telecommunication | |
Rural Utilities Service | 7 CFR 1755.910(d)(6)(ii) | ASTM A526/A 526M | 1990 | Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Commercial Quality | ASTM International | |
Rural Utilities Service | 7 CFR 1728.201(h)(2)(i) | AWPA P5 | 2008 | Standard for Waterborne Preservatives | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1728.202(f)(1)(v)(D) | AWPA A7 | 2004 | Standard Wet Ashing Procedure for Preparing Wood for Chemical Analysis | American Wood Protection Association | |
Rural Utilities Service | 7 CFR 1755.390(k)(7)(i) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.522(a)(9) | IEEE 730 | 1989 | Standard for Software Quality Assurance Plans | Institute of Electrical and Electronics Engineers | |
Rural Utilities Service | 7 CFR 1755.860(j)(3)(iii) | ASTM D1248 | 1989 | Standard Specification for Polyethylene Plastics Molding and Extrusion Materials | ASTM International | |
Rural Utilities Service | 7 CFR 1755.703(g)(5)(ii) | ICEA S-89-648 | 1993 | Standard for Telecommunications Aerial Service Wire, Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.870(h)(1)(iii) | ASTM D4566 | 1990 | Standard Test Method for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1755.890(k)(3) | ICEA S-84-608 | 1988 | Standard for Telecommunications Cable, Filed, Polyolefin Insulated, Copper Conductor Technical Requirements | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.903(c)(1) | ICEA S-110-717 | 2003 | Standard for Optical Drop Cable | Insulated Cable Engineers Association | |
Rural Utilities Service | 7 CFR 1755.902(c)(4)(i) | ASTM D4565 | 1999 | Standard Test Methods for Physical and Environmental Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable | ASTM International | |
Rural Utilities Service | 7 CFR 1755.910(e)(6)(v) | ASTM A526/A 526M | 1990 | Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Commercial Quality | ASTM International | |
Rural Utilities Service | 7 CFR 1755.902(r)(15)(iv)(F) | TIA/EIA 455-3A, FOTP-3 | 1989 | Procedure to Measure Temperature Cycling on Optical Fibers, Optical Cable, and Other Passive Fiber Optic Components | Electronic Industries Association and/or Telecommunications Industry Association | |
Rural Utilities Service | 7 CFR 1755.390(a)(7) | ASTM D4565 | 1990 | Standard Test Method for Physical and Environmental Performance Properties of Insulations and Jackets for Telecommunication Wire and Cable | ASTM International |